Tower Escape Apparatus
Operating Instructions
Catalog
1. Product name……………………………………………… 1
2. Model and specification………………………………… 1
3. Product overview………………………………………….. 2
4. Product users, application places……………………..3
5. Product structure drawing…………………………………………………….. 3
6. Operating method………………………………………………………………… 4
7. Common considerations……………………………………………………….. 6
8. Product advantage……………………………………………………………….. 7
9. Product care and maintenance……………………………………………… 7
10. After-sales service………………………………………………………………. 7
11. Maintenance CARDS…………………………………………………………… 8
12. Special remind…………………………………………………………………… 8
1. Product name
Tower Escape Apparatus is shorthand for TEA.
It is the best choice for people to get out of danger quickly when building and other high-rise building fire disaster and other emergencies. This product adopts advanced technology design and production, reliable and safe performance, simple operation. Using advanced centrifugal deceleration technology and all mechanical design, the tower escape apparatus can provide a quick way to escape the high-rise fire disaster immediately.
Tower escape device Item number definition
2. GZ escape deive model and specification
As shown above. The model and specification of Tower Escape Apparatus are composed of our company’s firefighting escape device trademark, the abbreviation of the product name, the installation location, the floor where the product is used and the position where the product is installed in the building.
The installation location: The “L” means that this escape device should be installed on the left side of the user’s balcony.The “R” means that the escape device should be installed on the right side of the user’s balcony. Depending on the floor height and location, each descent escape device is specifically designed in a different type and wire rope length to save cost and space
For example: GZ-TEAR-20-A tower escape apparatus
It is installed on the right of the balcony, suitable for installation in the high-rise 4-20 floors, the product installed in the balcony of the building. The maximum carrying capacity of this type of descent Rescue Device is 300Kg, which is suitable for the one-time safe escape of 4-5 people.
3. Tower escape apparatus product overview
More and more people work, live and play in the city’s high-rise buildings. But at the same time, high-rise fire disaster and other dangerous situations often happen that people have to face. Because of the lack of firefighting facilities in tower buildings, especially the escape device to deal with the fire disaster, people living in tower buildings when the fire disaster comes can only passively wait for rescue.
In the process, the fire disaster could endanger or even take their lives at any time. Our company independently developed this high-rise escape device, has been the national invention patent and utility model patent. The use of advanced centrifugal brake technology and all mechanical design, effectively solve the tower escape problem, let the fire disaster no longer become a killer. Centrifugal braking technology can control the descending speed of the hanging basket.
The maximum descending speed is independent of the weight and floor height within the allowable bearing range. The closer the vehicle is to the ground, the lower the descent speed, ensuring a smooth landing. The all-mechanical design eliminates the dependence of equipment operation on electricity and improves the reliability of equipment effectively.
The whole use of fireproof materials, can safely help people through the fire zone; In addition, the semi-enclosed structure of the hangers reduces people’s fear of fire and height. Simple operation, it only takes 3 steps to safely descend from the tower building to the ground. Our firefighting Escape Device are your best choice.
4. GZ escape device users, application places
Product users: Everyone including the elder, disable people and children all can use: All kinds of buildings with more than 3 floors, such as residential buildings, office buildings, teaching buildings, commercial buildings, Banks, medical buildings, hotels, entertainment places, etc.
5. GZ escape device structure drawing
The overall size after folding: 1015mmx375mmx250mm
Fast run escape device Case cover opening
Fast run escape device Large boom and brace opening
Fast fun escape device axis rotation
6. Tower escape apparatus operating Method
Product installation requirements: professional technical personnel trained by our company shall be responsible for the installation. The installation position of the escape device shall be determined by comprehensively considering the height of the user’s balcony, the width of the balcony, the overall length of the big boom and the small boom as well as other factors related to the building where the user is located. It shall be fixed on the wall through bolt installation.
Installation ensures stable and firm installation. After installation, fold up the parts and cover the chassis. When a fire disaster occurs, if you cannot use other escape routes to escape the scene quickly and safely, you should follow the following steps to use this product.
①Rotate the rotation switch on the bottom of the escape device case by 90° (you can first press the case cover with your left hand, and then rotate the switch with your right hand to prevent injury to people when the case cover is opened). The escape device case cover will open automatically under the action of the gas strut.
7. Tower escape apparatus common considerations
- Tower escape apparatus needs special technical personnel to install and debug, the non-technical personnel outside our company is prohibited to install, otherwise you should take the responsibility by yourself.
- Do not open the escape device case cover easily at ordinary times, it is only used in case of fire disaster.
- When the fire disaster occurs, all the escape personnel enter the hanging basket, buckle the safety button, and then press the rotary shaft to turn out handle.
- If there is an accident, immediately release the handle, the rotation axis will stop rotating.
8. GZ Tower escape apparatus advantages
Five core strengths of the product:
- Purely mechanical design, no electric drive, safe and reliable
- Simple operation steps, short escape time
- Heavy load, it can meet the needs of 4-5 people to escape at one time (450kg)
- The maximum rate of descent is independent of the height of the floor and the weight of the passengers.
- Adopt fireproof material, can pass through the fire disaster area safely
9. GZ Tower escape apparatus product care and maintenance
Products need regular maintenance and maintenance, every 2 years the company’s agents will send specialized technical personnel to the door service, product maintenance and maintenance
10. GZ Tower escape apparatus after-sales Service
Our company has a special department to track the sale of products and maintenance.
From the date of installation, our company will maintain for users free of charge for 10 years, maintenance every 2 years, with the replacement of parts beyond the safety period need to charge corresponding fees. Our company is also responsible for the maintenance of tower escape apparatus beyond the maintenance period, but the need to collect the appropriate maintenance fee.
(note: only those technicians who have received professional maintenance training and have been recognized in our company can accept the after-sales service of our products.)
11. GZ Tower escape apparatus maintenance CARDS
The escape device warranty card shall be carefully filled in and kept by the customer, and the maintenance card of the product shall be presented for each maintenance, and the maintenance record shall be made on the maintenance card.
If there is no maintenance card or the information on the maintenance card is inconsistent with the shipping data of the company, our company is not responsible for maintenance. Company’s mailing address and contact information is shown on the cover of the manual.
12. GZ Tower escape apparatus special remind
Please read the contents of this manual carefully before use. If the user violates the operation regulations of this manual and causes the use failure, the resulting adverse consequences are not within the scope of responsibility of this product